Namino

MPPV340 M6

4½ digit display in a 48x96 box for strain gauge (load cell) input. Optional 4 relay or 8 static alarms output and analogue and serial output.

The MPPV340 M6 model is an instrument with 16 bit A/D converter for strain gauge transducer.

The available measuring scales are listed in the "Features" section.

The instrument has the following functions:

  • 4½ digit indicator (± 19999)
  • reading of any input value inside the requested range
  • minimum or maximum peak measuring
  • reading at 30 conv/sec
  • "filtering" process for instrument readings
  • zeroing of automatic reading function

The MPPV340 M6 instruments can be ordered with the following options:

  • normal or optoisolated bidirectional serial output or monodirectional version for printer
  • 8 static alarm outputs or 4 relay alarm outputs for normal working or window alarms completely programmable for value, hysteresis and delay
  • Normal or optoisolated analogue output (4÷20mA or 0÷20mA or 0÷10V).
  • transducer power output stabilized at 10Vdc.

Readings: 4½ digit
Accuracy better than: 0,2%
Thermal stability: 50 ppm/°C
Transducer power supply: 10Vdc /90mA
Analogue outputs features:

  • Outputs: 4÷20mA - 0÷20mA - 0÷10V
  • Max load for current output: 400Ω
  • Min. load for voltage output: 1KΩ
  • Resolution: 16 bit

Exchange relay output: 5A / 250Vac
Static outputs NPN-PNP: 50mA/30Vdc
Power supply: 90÷260Vac/Vdc, 12÷30Vac/Vdc
Power absorption: 6W
Max working temperature: 50 °C
Digits height : 13mm
Dimensions: 48x96 (120 mm. Depth)
Mounting plate: 44.5mm (h) x 92.5 mm (l)
Weight: 350 gr.
Mounting: by bolts

OPTIONS AND SERIAL OUTPUTS

SR1÷3: 1÷3 relay alarms
SR4: 4 relay alarms without serial outputs
STN1÷8: 1÷8 NPN open collector static output alarms
STP1÷8: 1÷8 PNP open collector static output alarms
SNO1÷8: 1÷8 NPN open collector optoisolated static output alarms
SPO1÷8: 1÷8 PNP open collector optoisolated static output alarms

OAM: Analogue outputs (0÷20mA, 4÷20mA, 0÷10V)
OAT: Optoisolated analogue outputs (0÷20mA, 4÷20mA, 0÷10V)

Cod. 2: RS422 bi-directional
Cod. 3: RS 485 bi-directional
Cod. 4: RS 232 bi-directional
Cod. 12: RS 422 optoisolated bi-directional
Cod. 13: RS 485 optoisolated bi-directional
Cod. 14: RS 232 optoisolated bi-directional

MEASURING SCALES

MODELSENSIBILITYMODEL
MPPV 340 011mV/VMPPV 340 01
MPPV 340 021,5mV/VMPPV 340 02
MPPV 340 032mV/VMPPV 340 03
MPPV 340 043mV/VMPPV 340 04
MPPV 340 0510mV/VMPPV 340 05
termoregolatore
MP20 M1

4-digit Display (A, V) in 48x48.

visualizzatore
MP30 P2

4 digit display with fixed scale in a 36x72 box

visualizzatore
MP40 P6

4 digit display (A, V) in a 48x96 box.

display
MP45 P6

4 digit display (A, V) with two alarms in a 48x96 box.

visualizzatori
MPA-MPV-MPP P6

4-digit Display (A, V) in 48x96; 2 alarm relay; Analog output.

display
MPA - MPV M6

4½ digit display in a 48x96 box for AC or DC current or voltage input (A,V).

visualizzatori
MP1200 P6

4 digit display (A, V, J, K, S, PT100) in a 48x96 box; 2/3 alarms; analogue and serial outputs.

visualizzatori
MPM P6

4-digit Display (A, V) in 48x96; 2/3 alarm relay; Analog and serial outputs.

display
MPPV010 P6

OUT OF PRODUCTION - 5-digit Display for load cell in 48x96; 2/3 alarm relay; Analog and serial outputs.

display
MPP323 M6

4½ digit display in a 48x96 box for potentiometer transducer.

display
MPO347 M6

4½ digit display in a 48x96 box for Ohm measures (ohmmeter).

visualizzatori
MP2200 M6