MPA-MPV-MPP P6
4 digit display in a 48x96 box for DC or AC current input, DC or AC voltage input or potentiometer input. Optional 2 relays alarm outputs and analogue output or potentiometer input.
The MPA models with ammeter input or MPV models with voltmeter input or MPP models with potentiometer input are instruments with a dual slope converter for the measurement of D.C. or A.C. current or for positioning (using potentiometer transducers).
The scales available are listed in the "Features" section.
The instrument offers the following functions:
- 4 digit indicator (+9999 reading points)
- automatic reading zeroing
- transducer voltage power supply
- fixed zero (visualization from -1990 to 9990)
- reading at 4 conv/sec (no filter progr.)
The instruments of the MPA, MPV and MPP series can be ordered with analogue outputs and two alarm signals which are completely configurable for value, hysteresis and delay functions.
Readings: 4 digits
Accuracy input DC: < 0,5%
Accuracy input AC: 2%
Thermal stability: 50 ppm/°C
Transducer power supply* *: 14V/25mA (unregulated)
Potentiometers connectable (MPP): from 500Ω to 50KΩ
Potentiometer power supply: 2,5Vdc
Analogue outputs features:
- Outputs: 4÷20mA - 0÷20mA - 0÷10V
- Max load for current output: 400Ω
- Min. load for voltage output: 1KΩ
- Resolution: 12 bit
Exchange relay output: 5A / 250Vac
Power supply: 90÷260 Vac/Vdc, 25Vac, Vcc o Vpt (12÷30Vdc)
Power absorption: 1,5 W
Max working temperature: 50 °C
Digits height: 13mm
Dimensions: 48x96 ( 75 mm. Depth)
Mounting plate: 44.5mm (h) x 92.5 mm (l)
Weight: 250 gr.
Mounting: by bolts
** With dc power supply, Val=14Vdc if Vdc power supply >16Vdc
OPTIONS AND SERIAL OUTPUTS
SR2: Twin relay alarm
OAP: Analogue outputs
MEASURING SCALES
MODEL | MEASURING SCALES | INPUT IMPEDANCE |
MPA 15 | 22: (0)4÷20mAdc | 20Ω |
02: 1.999mAdc* | 100Ω | |
03: 19.99mAdc* | 10Ω | |
04: 199.9mAdc* | 1Ω | |
07: 1.999Adc* | 0,1Ω | |
08: 9.99Adc* | 0,005Ω | |
00: shunt ext.* | ∞ | |
MPA 35 | 02: 1.999mAac* | 100Ω |
03: 19.99mAac* | 10Ω | |
04: 199.9mAac* | 1Ω | |
07: 1.999Aac* | 0,1Ω | |
08: 9.99Aac* | 0,005Ω | |
10: T.A./1Aac | 0,1Ω | |
11: T.A./5Aac | 0,01Ω | |
MPP 125 | Potentiometer input | ∞ |
MPV 05 | 01: 199.9mVdc | ∞ |
02: 1.999Vdc | ∞ | |
03: 19.99Vdc | 1MΩ | |
04: 199.9Vdc | 1MΩ | |
05: 300Vdc | 1MΩ | |
06: 0÷1Vdc | 1MΩ | |
07: 0÷10Vdc | 1MΩ | |
08: 0÷100Vdc | 1MΩ | |
MPV 25 | 01: 199.9mVac* | ∞ |
02: 1.999Vac* | ∞ | |
03: 19.99Vac* | 1MΩ | |
04: 199.9Vac* | 1MΩ | |
05: 300Vac* | 1MΩ | |
06: 0÷1Vac* | 1MΩ | |
07: 0÷10Vac* | 1MΩ | |
08: 0÷100Vac* | 1MΩ |
* Instrument with DC power supply, with indicated scales, will have an opto-isolated power supply.