MP45 P6
OUT OF PRODUCTION - 4 digit display with two alarms in a 48x96 box for DC or AC voltage, DC or AC current measures or potentiometer input.
The MP45 P6 model is programmable with 2 relay alarms.
The available scales are shown in the "Features" section.
The instrument offers the following functions :
- 4 digit display for DC inputs (-1999 +9999 reading points), 3200 digits for AC inputs.
- automatic reading zeroing
- transducer voltage power supply
- fixed zero (visualisation from -1990 to 9990)
- programmed filter (from 0,5 to 33 conv/sec)
- 2 relay alarm outputs programmable for value, hysteresis and delay.
Readings: 4 digits
Accuracy input DC: < 0,5%
Accuracy input AC: 2%
Thermal stability: 50 ppm/°C
Transducer power supply* *: 14V/25mA (unregulated)
Potentiometers connectable: from 500Ω to 50KΩ
Potentiometer power supply: 2,0Vdc
Power supply: 25Vac 50÷60Hz | 115Vac 50÷60Hz | 230Vac 50÷60Hz | Vcc o Vpt (12÷30Vdc)
Exchange relay output: 5A / 250Vac
Power absorption: 1,5 W
Max working temperature: 50 °C
Digits height: 13mm
Dimensions: 48x96 (75 mm. Depth)
Mounting plate: 44.5mm (h) x 92.5 mm (l)
Weight: 250 gr.
Mounting: by bolts
** With dc power supply, Val=14Vdc if Vdc power supply >16Vdc
MEASURING SCALES
MODEL | MEASURING SCALES | INPUT IMPEDANCE |
MP45 AA | 01: 1.999mAac* | 100Ω |
02: 19.99mAac* | 10Ω | |
03: 199.9mAac* | 1Ω | |
04: 1.999Aac* | 0.1Ω | |
05: 9.99Aac* | 0.005Ω | |
06: T.A./1Aac | 0.1Ω | |
07: T.A./5Aac | 0.01Ω | |
MP45 AD | 01: (0)4÷20mAdc | 20Ω |
02: 1.999mAdc* | 100Ω | |
03: 19.99mAdc* | 10Ω | |
04: 199.9mAdc* | 1Ω | |
05: 1.999Adc* | 0.1Ω | |
06: 9.99Adc* | 0.005Ω | |
07: shunt ext.* | ∞ | |
MP45 PO | Potentiometer input | ∞ |
MP45 VA | 01: 199.9mVac* | ∞ |
02: 1.999Vac* | ∞ | |
03: 19.99Vac* | 1MΩ | |
04: 199.9Vac* | 1MΩ | |
05: 300Vac* | 1MΩ | |
06: 0÷1Vac* | 1MΩ | |
07: 0÷10Vac* | 1MΩ | |
08: 0÷100Vac* | 1MΩ | |
MP45 VD | 01: 199.9mVdc | ∞ |
02: 1.999Vdc | ∞ | |
03: 19.99Vdc | 1MΩ | |
04: 199.9Vdc | 1MΩ | |
05: 300Vdc | 1MΩ | |
06: 0÷1Vdc | 1MΩ | |
07: 0÷10Vdc | 1MΩ | |
08: 0÷100Vdc | 1MΩ |
* Instrument with DC power supply, with indicated scales, will have an opto-isolated power supply